{"product_id":"ecumaster-pmu24-dl-power-management-unit","title":"ECUMaster PMU-24 Datalogging","description":"\u003cp\u003e\u003cspan\u003eThe PMU-24 DL is a new and enhanced Power Management Unit featuring all of the amazing functionality of the PMU-16, now with 24 high-side outputs and internal data logging memory as standard. Through clever engineering, 8 of the analog inputs may be utilized as 7 amp high side outputs. As standard with the PMU-16 series, all output states, voltage, and current information are able to be transmitted via CAN bus to a dash display to inform the driver of potential problems. In addition, all internally logged data can be downloaded from the device for later analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 491px;\" height=\"488\" width=\"400\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e170 Amp continuous current capacity. \u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eOperating voltage: 6-22V (immunity to transients according to ISO 7637)\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eTemperature range: AECQ-100 GRADE 1, -40 to +125°C.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e10x 25 Amp high-side power outputs (PWM capable).\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e6x 15 Amp high-side power outputs.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e8x 7 Amp high-side power outputs.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eUp to 16 analog inputs.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e24x tricolor LED for each power output state.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e2x CAN 2.0 A\/B.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e256 MB data logger memory.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eUp to 500 Hz logging frequency.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eReal-time clock for data stamping.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003e3D accelerometer\/gyroscope.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eBuilt-in “inertia switch” in case of an accident.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eEasy access to CAN-bus data (imports and exports).\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eInternal data processing using logical functions, numbers, timers, and tables.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eCustom PID controllers.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eFully customizable ”logic” for each output.\u003c\/td\u003e\n\u003ctd style=\"width: 14.2812px;\" data-mce-style=\"width: 14.2812px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 460.719px;\" data-mce-style=\"width: 460.719px;\"\u003eFlexible and intuitive client software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Documents\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.ecumaster.com\/files\/PMU\/PMU-24_Pinout_mini_v1.0.pdf\" target=\"_blank\"\u003ePMU-24 DL Pinout Simplified\u003c\/a\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.ecumaster.com\/files\/PMU\/PMU-24_Pinout_v1.0.pdf\" target=\"_blank\"\u003ePMU-24 DL Pinout Advanced\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.ecumaster.com\/files\/PMU\/PMU_Manual.pdf\" target=\"_blank\"\u003ePMU User Manual 92.0\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ecumaster.com\/wp\/wp-content\/uploads\/2022\/11\/pmu_comparison_np_v2.pdf\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePMU Comparison Chart\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.ecumaster.com\/files\/PMU\/PMU-24_CAD_data.zip\" target=\"_blank\"\u003ePMU-24 DL CAD Data\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ecumaster.com\/wp\/wp-content\/uploads\/2023\/01\/PMU24.pdf\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDrawings - PMU-24 DL\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ECUMaster","offers":[{"title":"Default Title","offer_id":60328891679006,"sku":"ECUPMU24DL","price":2932.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0976\/9992\/2206\/files\/PMU24DL_01_f2773582-76f8-4d28-941f-6a366851c45c.jpg?v=1792086339","url":"https:\/\/connectorkits.com\/products\/ecumaster-pmu24-dl-power-management-unit","provider":"ConnectorKits.com","version":"1.0","type":"link"}